pattern

Capabilities

If we have the belief that we can do it, we shall surely acquire the capacity to do it even if we may not have it at the beginning, Keeping that belief, we have grown and keep growing

Our Capabilities

Every action & decision we take – into the futurewe have the Capability, the Technology, & the Knowledge added

ENVIRONMENTAL SIMULATION LAB
SL TYPE MAKE MODEL RANGE
1. Altitude Test Capacity
(Temperature, Humidity and Altitude)
Envisys EA650 VOLUME: 650L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 5°C/min
ALTITUDE RANGE: UP TO 30,000 meters (1Lakh Feet)
2. Walk-In Type
Thermal Test Capacity
Envisys EWS22K VOLUME: 22000L
TEMPERATURE RANGE: -40°C to +85°C
HUMIDITY RANGE: 30 to 95%
RAMP RATE: 2°C/min
3. Temperature/Humidity
(Fast Ramp Rate)
Envisys ET950 VOLUME: 950L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 20°C/min
4. Temperature/Humidity
Test Capacity
Thermotron SE3000 VOLUME: 3000L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 5°C/min
5. Temperature/Humidity
Test Capacity
Thermotron SE3000 VOLUME: 3000L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 5°C/min
6. Temperature/Humidity
Test Capacity
Thermotron SE1400 VOLUME: 1400L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: NA
RAMP RATE: 3°C/min
7. Temperature/Humidity
Test Capacity
Thermotron SM27 VOLUME: 870L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 3°C/min
8. Temperature/Humidity
Test Capacity
Envisys ET950 VOLUME: 950L
TEMPERATURE RANGE: -73°C to +170°C
HUMIDITY RANGE: 10 to 95%
RAMP RATE: 5°C/min
9. Temperature/Humidity
Test Capacity
Design Environmental Alpha VOLUME: 900L
TEMPERATURE RANGE: -40°C to +170°C
HUMIDITY RANGE: 30 to 95%
RAMP RATE: 3°C/min
10. Temperature/Humidity
Test Capacity
Design Environmental Delta VOLUME: 950L
TEMPERATURE RANGE: -40°C to +170°C
HUMIDITY RANGE: 30 to 95%
RAMP RATE: 3°C/min
11. Temperature/Humidity
Test Capacity
Envisys ETMG265 VOLUME: 300L
TEMPERATURE RANGE: +10°C to +120°C
HUMIDITY RANGE: 40 to 98%
RAMP RATE: 1°C/min
12. Thermal Shock Envisys TC100 VOLUME: 100L
TYPE: Basket movement between HOT and COLD Cabinets
TEMPERATURE RANGE: -73°C to +180°C
RAMP RATE: Less Than 10 Seconds
13. Hot Air Test Capacity Terchy NCK-290 VOLUME: 350L
TEMPERATURE RANGE: Lab Ambient to +200°C
14. Fluid Contamination
Test Capacity
Envisys EAR160 VOLUME: 120L
TEMPERATURE RANGE: Lab Ambient to +80°C
HUMIDITY RANGE: NA
RAMP RATE: 1°C/min
15. Fluid Contamination
Test Capacity
Envisys EAR160 VOLUME: 120L
TEMPERATURE RANGE: Lab Ambient to +80°C
HUMIDITY RANGE: NA
RAMP RATE: 1°C/min
16. Fluid Contamination
Test Capacity
Envisys EAR160 VOLUME: 120L
TEMPERATURE RANGE: Lab Ambient to +80°C
HUMIDITY RANGE: NA
RAMP RATE: 1°C/min
17. Sealing / Fine Mist RaaGoma R129J-13 VOLUME: 1000L
TEMPERATURE RANGE: Ambient
18. Salt Spray Envisys ECS300 VOLUME: 300L
TEMPERATURE RANGE: Lab Ambient to +60°C
HUMIDITY RANGE: 40 to 98%
19. DUST – IP 5X and 6X Envisys EDC2700 VOLUME: 1500L
TEMPERATURE RANGE: Lab Ambient to +60°C
RANGE: Vacuum Suction up to 5 ports
DUST VOLUME Measurement
20. DUST – JSS Envisys EDC1000 VOLUME: 1000L
TEMPERATURE RANGE: Lab Ambient to +60°C
HUMIDITY RANGE: 40 to 98%
AGITATOR METHOD DUST CIRCULATION
DYNAMICS AND VIBRATION TEST LAB
SL TYPE MAKE MODEL RANGE
1. Vibration Test (4 Ton) DESPL DEV-440 Force Rating: 4.0Ton (4000Kgf)
Frequency Range: 5 – 2500 Hz
Acceleration: up to 90g
Displacement: 50mm P-P
Table Size: 1000 X 1000 mm
Profile Supported: Swept Sine/Resonance,
Random Vibration, Sine on Random (SOR),
Random On Random (ROR), Classical Shock (Half Sine,
Terminal Peak Saw Tooth, Initial Peak Saw Tooth,
Triangle, Rectangle, Trapezoidal, & Haver Sine)
2. Vibration Test (2 Ton) DESPL DEV-300 Force Rating: 2.0Ton (2000Kgf)
Frequency Range: 5 – 2500 Hz
Acceleration: up to 90g
Displacement: 75mm P-P
Table Size: 600 X 600 mm
Profile Supported: Swept Sine/Resonance, Random Vibration,
Sine on Random (SOR), Random On Random (ROR),
Classical Shock (Half Sine, Terminal Peak Saw Tooth,
Initial Peak Saw Tooth, Triangle, Rectangle, Trapezoidal,
& Haver Sine)
3. Drop Test RaaGoma Tech Private Limited R129e Drop Height: up to 1500 mm
Platform Size: 1000 X 1000 mm
Type of drop: Free fall with Face, Corner, Edge drop support
Drop surface: Wood, Concert, Sand & Steel surfacer
4. Acoustics and NVH SINUS Mess Technik GmBH BOX_LT_4B SOUND POWER / SOUND INTENSITY
Frequency range: 20Hz to 20000Hz
Processing tools: loudness, sharpness, tonal, octave.
Frequency weighting (A, C, D available).
Profiles: Sound source localization / Sound power calculations,
Sound intensity measurements performed in-situ, customer site,
Order Tracking Measurement on Rotating Equipment.
5. MODAL ANALYSIS SINUS Mess Technik GmBH BOX_LT_4B FRF Measurements.
Siso, Simo, Miso, Mimo Modal Testing Methods
Impact Hammer Operation Mode
Advanced Modal Analysis
Operational Modal Analysis (Oma)
Geometry Unv Import/Export
6. IK Test DANYRIYAS ENGINEERS DRE-SPM-005 Code IK: IK01 to IK10
Workspace: 1000 X 1000 mm
Usable size: 1000 X 1000 mm
MILITARY STANDARD: AIRCRAFT ELECTRIC POWER CHARACTERISTICS TEST LAB
SL TYPE MAKE MODEL RANGE
1. Programmable Power Supply
(AC/DC)
Ametek Inc AST 3003 DC Voltage: 0 to 500V; DC Current: 0 to 30A;
AC Voltage: 0 to 400V; AC Current: 0 to 30A;
Frequency: 16 to 1200 Hz.
Avionics Electrical Power Quality Test Software – includes 160
(RTCA/DO160 E/F/G), 704 (MILSTD 704 A/B/C/D/E/F),
ABD (Airbus ADB100.1.8 D/E),A350 (Airbus ADB100.1.8.1 B/C)
ELECTRICAL SAFETY TEST LAB
SL TYPE MAKE MODEL RANGE
1. Programmable Electrical
Safety Tester
Clare H103 Insulation Test:250 V to 1000 V;
Leakage Current: 0 to 20mA;
Ground Bond: 0 to 30A
2. Programable AC power Source Pacific Smart Source PACIF1 Rated Power: 1,200VA;
Frequency: 20-5,000 Hz;
Phase: 1 and 2 Phase.
3. Digital Power Meter Yokogawa WT230 AC Voltage: 15 to 600V;
AC Current: 500mA to 20A;
AC Power (PF=1.00);
Voltage Range: 120 to 240V;
Current Range: 0.1 to 20A.
WIRELESS AND TELECOMMUNICATIONS TEST LAB
SL TYPE MAKE MODEL RANGE
1. Wireless Communications
Test Set
Agilent 8960 Series E5515C LAN: RJ-45 connector, 10 base T Ethernet with TCP/IP support;
Frequency Range: 292 to 2700 MHz;
Output level range with modulation: -110 to -13 dBm;
Voltage Standing Wave Ratio: < 1.2:1 400 to 2000 MHz;
2. Universal Radio
Communication Tester
ROHDE & SCHWARZ CMU 200 Frequency range: 100 kHz to 2700 MHz;
Frequency resolution: 0.1 Hz
3. Serial Data Analyzer Lecroy SDA 6000A Analog Bandwidth at 50 Ω (-3 dB): 6 GHz;
Rise Time: 75 ps;
Number of Input Channels: 4;
Bandwidth Limiters: 20 MHz, 200 MHz, 1 GHz,3 GHz, 4 GHz;
Input Impedance: 50 Ω ±2%;
Input Coupling: DC, GND (SDA 3010: DC, GND, DC 1MΩ, AC 1MΩ);
4. Traffic Generator
(100G Modules)
Viavi Solutions MAP-2100 Physical Ports: 1 x CFP42 x QSFP28;
2 x SFP28; 1 x RJ-45 for 10/100/1000Base-T;
1 x RJ-48c; 2 x Mini-BNC; 1 x SMA for GNSS Antenna;
1 x CLK IN/OUT; 1 x 1PPS IN REF; 1 x EXT;
Supports: Ethernet, OTN, SONET/SDH, PDH,
Fibre Channel up to 32G Ethernet testing,
1G through 100G line rates (10G, 25G, 40G, 100G)
enhanced RFC 2544.
5. Electrical Jitter Viavi Solutions MTS -5800 V2 Physical Ports: RJ-45, SFP, QSFP port, T3, STS1, E3, E4, STM-1e;
Power Supply :100 to 240 V AC, 50/60 Hz, Auto-switching;
Testing: Automated, enhanced RFC 2544 and SAM
Complete testing per ITU-T .1564 1G.
6. Optical Parameter Tester
(MAP200 Optical Power Meter)
Viavi Solutions mOPM-C1PMH1-MPMGP Measures power levels: -70 to +11 dBm;
Wavelength range:800 to 1650nm; Detector Size:2mm.
7. Optical Parameter Tester
(O Band Amplifier 1310nm)
Viavi Solutions mSRC-C23000SA-M100-MFA Operating Wavelength Range:1270 nm–1340nm;
Input Power Range: -30 to 3dBm; Fibre Type: single Mode.
8. Optical Parameter Tester
(C Band Amplifier)
Viavi Solutions mEDFA-C11CA-M100-MAF Operating Wavelength Range:1528nm–1569nm;
Maximum input power:>20dBm; Fibre Type: single Mode.
9. Optical Parameter Tester
(MAP Series Variable Optical Attenuator)
Viavi Solutions mVOA-C1SS0-M100-MLU Operating Wavelength Range:1260nm–1650nm;
Maximum input power:23dBm;
Attenuation range:70dB;
Connector type: LC/PC.
10. Optical Spectrum analyser Viavi Solutions MTS-8000 Wavelength range:800 to 1650nm in 1nm steps;
Measurementrange: +5 to −50dBm;
Connector type: Universal push/pull (UPP).
11. PON Power meter Viavi Solutions OLP 87- XG-PON Wavelength Range:1260 to 1625nm;
Power measurements: -35dBm to +9dBm.
12. NG PON Power meter Viavi Solutions OLP 87- NG-PON Wavelength Range:1310nm to 1490nm;
Power measurements: -27dBm to +8dBm;
13. E1 Return Loss Viavi Solutions HST-3000 Wavelength Range:1310nm to 1490nm;
Power measurements: B PON, G PON, E PON.
14. PON Analyzer Viavi Solutions OLP-88 Wavelength Range:1310nm to 1490nm;
Power measurements: B PON, GPON, E PON.
MATERIALS AND METALLURGICAL TEST LAB
SL TYPE MAKE MODEL RANGE
1. Metallurgical Microscopic Chennai Metco Vertimet Pro Eyepiece: 10X Objectives: 5X, 10X, 20X, 50X, 100X optional
Magnification Range: 50X -500X (Standard)
Illumination: 12V, LED
Moving range: 76mmX42mm.
2. Grinding/Polishing Machine Chennai Metco PMV018 0.5 HP high torque AC motor
Imported AC Drive
8″, 10” & 12” disc dia. standard
50 to 1000 RPM or 50 to 600 RPM
3. Digital Rockwell Hardness Tester Chennai Metco RASNET-3 Testing load: 60, 100, 150 kfg
Conversion scale: superficial Rockwell, Brinell, Vickers
Distance of indenter to outer wall: 160 mm
Max. height of specimen: 220 mm
Rockwell Scale: HRA, HRB, HRC, HRD, HRE, HRF,
HRG, HRH, HRK, HRL, HRM, HRR, HRP, HRS, HRV
Conversion scale: Superficial Rockwell, Brinell, Vickers
Hardness measuring range: HRA:20-88, HRB:20-100, HRC:20-70, HRD:40-77,
HRE:70-100, HRF:60-100, HRG:30-94, HRH:80-100, HRK:40-100,
HRL:100-120, HRM:85-115, HRR:114-125 Max. Height of Specimen: 220 mm
4. Micro-Vickers Hardness tester Chennai Metco MMT-X8 Digital Vickers Hardness Tester (Matsuzawa – Japan)
Testing load: 0.3,0.5,1,3,5,10,20,30, Kgf
Loading mechanism: Automatic Loading and Releasing Method
Dwell time : 5 to 99 sec
Min: Measuring: 0.1 Micrometre
Max. Measuring length: 999.9 Micrometre
Magnification of Microscope: 100 x & 200X
height and depth of specimen: 260 mm x 160 mm
Load applying Speed: 85 micrometre/sec
5. Universal Test Machine RaaGoma DS105A4 Force Capacity: 2000Kg (2 ton)
Crosshead Travel: 1407mm
Vertical Test Space: 1494mm
Horizontal Test Space: 575mm